Desain Sistem Proteksi Arus Lebih PLTU Sungai Maya | ELECTRONIC THESES AND DISSERTATION
Image of Desain Sistem Proteksi Arus Lebih PLTU Sungai Maya

Desain Sistem Proteksi Arus Lebih PLTU Sungai Maya

Pengarang : Muhammad Riska - Personal Name;

Perpustakaan UBT : Universitas Borneo Tarakan., 2013
XML Detail Export Citation
    SKRIPSI

Abstract

Sistem proteksi arus lebih adalah salah satu jenis peralatan proteksi yang digunakan untuk mendeteksi gangguan beban lebih dan gangguan hubung singkat, baik satu fasa ke tanah, fasa ke fasa, dua fasa ke tanah maupun tiga fasa/simetris. Untuk menjamin keandalan, relai pengaman harus memenuhi persyaratan, yaitu kecepatan bereaksi, kepekaan operasi, selektif dan andal. Oleh sebab itu dibutuhkan settingan yang tepat agar relai pengaman dapat bekerja sesuai dengan yang diinginkan. Dengan tahap awal PLTU Sungai Maya sebesar 2x7 MW, tegangan 20 kV, saluran ganda AAAC 3x240 mm ,maka dibutuhkan sistem proteksi yang baik. Dalam penelitian ini dilakukan kajian mengenai analisa settingan relai arus lebih. Dari hasil penelitian didapatkan bahwa merk atau jenis relai yang akan digunakan adalah GE multilin yang didalamnya terdapat proteksi Over Current Relay (OCR), instantaneous OCR, Ground Fault Relay (GFR) dan instantaneous GFR. Dengan nilai setting arus relai OCR sebesar 5,094 A, arus relai instantaneous OCR sebesar 5,094 A, arus relai GFR sebesar 0,63 A dan arus relai instantaneous GFR sebesar 7,64 A.

The over current protection system is one type of protective equipment that is used to detect overload disorders and short circuit, either a single phase to ground, phase-to-phase, two-phase and three-phase to ground / symmetrical. To ensure reliability, safety relays must meet the requirements, namely the speed of reaction, sensitivity operation, selective and reliable. Therefore, it takes the right setting so that the safety relay can work as expected. On the early stages of PLTU for 2x7 MW Maya River, a voltage of 20 kV, 3x240 mm AAAC dual channel, it takes a good protection system. In this study conducted a study on the analysis of over current relay settings. The result showed that the brand or type of relays that will be used is GE multilin in which there is protection Over Current Relay (OCR), OCRinstantaneous, Ground Fault Relay (GFR) and GFR instantaneous. With the value of the current setting of 5.094 relays OCR A, OCR instantaneous relay currents of 5.094 A, GFR relays currents of 0.63 A and the current instantaneous relay GFR of 7.64 A.

Detail Informasi