Analisa Efektivitas Incinerator Limbah Medis Dengan Menggunakan Metode OEE (Overall Equipment Effectiveness)
Pengarang : Judesen Sampe Pakiding - Personal Name;
Perpustakaan UBT : Universitas Borneo Tarakan., 2023XML Detail Export Citation
Abstract
Limbah medis yang terdapat di rumah sakit dikategorikan sebagai limbah bahan berbahaya beracun (B3), limbah ini harus diolah dengan pengolahan yang benar agar tidak memberikan dampak negatif bagi lingkungan. Salah satu upaya pengolahan limbah medis adalah dengan cara dibakar. Untuk pembakaran menggunakan mesin incinerator, peralatan pembakarannya menggunakan burner dan disertai blower untuk proses pembakaran lebih sempurna. Berdasarkan latar belakang, penelitian ini dilakukan untuk mengetahui efektivitas ketersedian dan kualitas output mesin atau peralatan pada incinerator dengan menggunakan metode OEE (Overall Equipment Effectiveness). Setelah penelitian dilakukan, rata-rata nilai perhitungan OEE pada mesin incinerator adalah 50%, dapat disimpulkan efektivitas incinerator limbah medis masih dibawah standar jika dibandingkan dengan nilai ideal OEE yaitu sebesar 85%. Banyaknya waktu henti pada mesin burner dan rendahnya performa daya mesin blower serta banyaknya limbah yang tidak sesuai untuk diolah mengakibatkan turunnya tiga rasio utama OEE yaitu nilai Avaibility, Performance, dan Quality pada incinerator sehingga nilai efektivitas pada mesin incinerator limbah medis tidak dapat mencapai nilai ideal standar OEE (Overall Equipment Effectiveness)
Kata kunci : Incinerator, Blower, Burner, OEE, Limbah Medis
Medical waste found in hospitals was categorized as toxic hazardous material waste (B3) In order to avoid harming the environment, this waste needs to receive the right treatment. One of the medical waste treatment efforts is by incineration. For a more efficient combustion process while using an incineration machine, the combustion equipment employs a burner and is accompanied by a blower. Based on the background, this research was conducted to find out the effectiveness of availability and output quality of machines or equipment in the incinerator by using the OEE (Overall Equipment Effectiveness) method. The average OEE calculation value of the incineration machine after the research was completed was 50%, and it was established that the medical waste incinerator's efficacy was still below the optimum OEE value of 85%. The amount of downtime in the burner engine and the low power performance of the blower engine and the amount of waste that was not suitable for processing resulted in a decrease in the three main ratios of OEE, namely avaibility, performance, and quality in the incinerator, so that the effectiveness of the medical waste incinerator machine could not reach the standard ideal value OEE (Overall Equipment Effectiveness). Keywords: Medical Waste Incinerator, Blower, Burner, OEE